STEEL CONNECTION DESIGN · PHASES 1–7
Bolt Capacity Calculator for Steel Connections
Check bolt shear, tension, bearing, HSFG slip resistance, bolt-group distribution, connected-plate strength and complete bearing-bolt connections to IS 800:2007.
Bolt shear capacity
Double shear · 2 planes
Connection shear check
Selected fastener
Step-by-step calculation
Enter the connection details and calculate to generate the code-based calculation report.
IS 800:2007, Clauses 6.2, 6.3.1, 6.4.1, 10.3.1, 10.3.3–10.3.6 and 10.4.3–10.4.6. The complete checker uses elastic shear-group forces, uniform bolt tension sharing and a bearing-type bolt interaction check. HSFG, prying and eccentric tension redistribution are outside its scope.
View IS 800:2007 source PDF ↗This calculator is intended for educational and preliminary engineering design checks. Results are based on the selected design code, entered inputs and implemented calculation assumptions. The engineer must independently verify all input data, applicable code provisions, connection detailing, fabrication requirements and complete structural design before using results in actual projects. This tool does not replace professional engineering judgment or independent design review.
Scope: Phases 1–7 combine bearing-bolt, bolt-group and plate limit-state checks for a selected geometry. The full connection module assumes uniform bolt tension and is not an HSFG design. Prying, tension redistribution from eccentric moment, long-joint/grip-length effects, welds, stiffeners, and installation verification remain outside scope.
STEEL BOLT DESIGN GUIDE
Steel Bolt Design Calculator for IS 800:2007
Use this bolt capacity calculator to review common bolted steel connection limit states against IS 800:2007. Choose a bolt grade and diameter, enter the connection geometry and factored loads, then review the design resistance, utilization ratio and calculation steps. The tool is intended for preliminary checks by structural engineers, civil engineers, steel detailers and engineering students. Open the bolt calculators.
Bolt shear, tension and bearing capacity
The bolt shear capacity calculator uses the selected number of shear planes and whether threads cross the shear plane. IS 800 design shear resistance is checked against bearing resistance on the connected plate. The bolt tension calculator checks direct tensile resistance using the entered bolt yield strength and tensile stress area. Bolt bearing capacity depends on bolt diameter, plate thickness and strength, hole size, end distance and pitch.
HSFG bolt slip resistance and combined loading
The HSFG bolt slip calculator estimates slip resistance from the selected slip factor, friction interfaces, hole condition and pretension. For bearing-type bolts, the combined shear and tension check reports the interaction expression used by IS 800. Confirm surface preparation, bolt installation and material properties from the project documents before relying on these inputs.
Eccentric bolt groups and connected plate strength
The bolt group capacity calculator distributes direct shear and applied moment across a user-defined bolt layout using an elastic method. It reports the force and utilization at each bolt, including the governing bolt. Connected-plate checks include gross-section yielding, net-section rupture, block shear and plate bearing. Enter gross and net failure-path areas from the actual detail; the schematic does not derive those dimensions.
How to use the IS 800 bolt design calculator
- Select a calculator or complete-connection check.
- Enter bolt properties, plate strengths, connection dimensions and factored loads.
- Calculate and review the governing limit state, individual demands, design resistance and assumptions.
Results are preliminary design checks. Verify all applicable detailing, load combinations, connected parts, fabrication requirements and code provisions independently.
Frequently asked questions about bolt capacity
What does a bolt capacity calculator check?
It estimates selected bolt and connected-plate design resistances, then compares them with the applied factored forces. The governing check is the limit state with the highest utilization among the checks included in the selected module.
How is bolt shear capacity checked to IS 800?
For bearing-type bolts, design shear resistance depends on bolt ultimate strength, effective shear area and the number of shear planes. The design bolt strength is limited by the smaller of bolt shear and bolt bearing resistance as required by IS 800.
Do threads affect bolt shear strength?
Yes. If threads cross the shear plane, the effective area is smaller than the plain shank area. Use the threaded-area option unless the connection detail confirms the shear plane is in the unthreaded shank.
What is block shear failure in a bolted plate?
Block shear is a connected-plate failure path involving shear along bolt lines and tension across an end section. The block shear calculator checks both IS 800 mechanisms using gross and net path areas entered for the actual detail.
Can I use the result as final connection approval?
No. This calculator provides preliminary checks only. It does not cover every connection failure mode, detailing requirement, construction condition or project-specific design rule. A qualified engineer must verify the complete connection.